CM310 is a recombinant humanized monoclonal antibody targeting Interleukin (IL)-4 receptor alpha (IL-4Rα). IL-4Rα blockade prevents IL-4 and IL-13 from binding to their receptor, thereby inhibiting downstream signaling pathways that drive Type 2 helper T-cell (Th2) inflammation. CM310 holds potential for treating Th2-related inflammatory diseases, such as asthma, atopic dermatitis and chronic sinusitis with nasal polyposis. In this study, a direct enzyme-linked immunosorbent assay (ELISA) was developed to measure the concentrations of CM310 in rat serum. Seven calibration standards (ranging from 25 to 1600 ng/mL) and three quality controls (70, 500 and 1250 ng/mL) were defined. The limit of detection (LOD), lower limit of quantification (LLOQ) and upper limit of quantification (ULOQ) were 13, 25 and 1600 ng/mL, respectively. The method exhibited excellent precision and accuracy and successfully applied to in vitro serum stability and pharmacokinetic (PK) studies. In conclusion, we have developed and validated a highly sensitive and selective method for measuring CM310 in Sprague-Dawley rats. The development and validation ELISA method met the acceptable criteria, which suggested that these can be applied to quantify CM310, as well as in PK studies.